Skip Navigation

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (12)
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Klemic, G.
Right arrow Articles by Moscovitch, M.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Klemic, G.
Right arrow Articles by Moscovitch, M.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Radiation Protection Dosimetry 85:201-206 (1999)
© 1999 Oxford University Press

State of the Art of Environmental Dosimetry: 11th International Intercomparison and Proposed Performance Tests

G. Klemic, J. Shobe, S. Sengupta, P. Shebell, K. Miller, P.T. Carolan, G. Holeman, H. Kahnhauser, P. Lamperti, C. Soares, N. Azziz and M. Moscovitch (INVITED)

The eleventh international intercomparison of environmental dosemeters was organised by the Environmental Measurements Laboratory in collaboration with the National Institute of Standards and Technology (NIST) and Brookhaven National Laboratory. One hundred and twenty one participants from 31 countries submitted 174 sets of dosemeters, including thermoluminescence dosemeters (TLDs), film, electrets, and a Geiger-Mueller device. An outdoor field site was used to expose dosemeters to natural radiation for three months, while other dosemeters were exposed to 137Cs and 241Am laboratory sources. A pressurised ionisation chamber, operated continuously at the field site, provided an independent measure of the air kerma in the field, and laboratory air kerma values were verified with chambers calibrated by NIST. Results are presented and current issues in environmental dosimetry are highlighted, including the field performance of new hypersensitive TLD materials. Preliminary results are given from a pilot test of a proposed standard from the American National Standards Institute that provides performance test criteria for environmental dosemeters.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Radiat Prot DosimetryHome page
M. Stuhec, B. Zorko, D. Mitic, S. Miljanic, and M. Ranogajec-Komor
Quality assurance of environmental gamma radiation monitoring in Slovenia
Radiat Prot Dosimetry, December 1, 2006; 121(2): 191 - 194.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
B. Marczewska, P. Bilski, P. Olko, M. Nesladek, M. Rebisz, and M. J. Guerrero
On the dose response of some CVD diamond thermoluminescent detectors
Radiat Prot Dosimetry, September 1, 2006; 119(1-4): 319 - 322.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.