Skip Navigation

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (10)
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Morelli, B.
Right arrow Articles by Fantuzzi, E.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Morelli, B.
Right arrow Articles by Fantuzzi, E.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Radiation Protection Dosimetry 85:105-108 (1999)
© 1999 Oxford University Press

Dosimetric Performance of the Fast Neutron Dosemeter for ENEA Personal Dosimetry Service

B. Morelli, E. Vilela and E. Fantuzzi

The Institute for Radiation Protection of ENEA has employed for many years a solid state nuclear track detector CR-39 as a fast neutron personal dosemeter with good results. The 1990 recommendations of ICRP 60 has introduced new parameters to neutron dosimetry that require harmonisation of the dosemeters' response within international recommendations. This paper reports the results of an experimental study performed at ENEA in order to investigate the dosimetric performance of two kinds of CR-39 produced in UK and Italy. Sensitivity, lowest detectable dose, background, linearity, energy and angular responses are compared between the two CR-39 materials. Irradiation tests have been performed with monoenergetic neutron beams in the range from 100 keV to 20 MeV, as well as with 252Cf and 241Am-Be sources. The Italian CR-39 material, used elsewhere for heavy ions detection in scientific applications, has here been comprehensively tested for neutron dosimetry purposes. Results were very satisfactory and it has therefore been introduced in the ENEA Personal Dosimetry Service.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Radiat Prot DosimetryHome page
B. Morelli, F. Mariotti, and E. Fantuzzi
The ENEA neutron personal dosimetry service
Radiat Prot Dosimetry, September 1, 2006; 120(1-4): 312 - 315.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.