Skip Navigation

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (4)
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Preece, A.W.
Right arrow Articles by Golding, J.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Preece, A.W.
Right arrow Articles by Golding, J.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Radiation Protection Dosimetry 83:21-27 (1999)
© 1999 Oxford University Press

Assessment of Human Exposure to Magnetic Fields Produced by Domestic Appliances

A.W. Preece, W.T. Kaune, P. Grainger and J. Golding (INVITED)

A study of 50 homes and their appliances examined whether a detailed appliance-use questionnaire and survey would yield data comparable with direct personal monitoring. This was coupled with direct measurement of the appliances in use to determine the field at 50 cm and 1 m. The findings were that individual time-weighted average (TWA) exposures calculated from questionnaire and activity diaries in conjunction with the appliance magnetic field were unrelated to actual personal exposure measurement. It was concluded that questionnaires are of little or no value for TWA estimation. However, peak exposure and short-term temporal variability could be modelled in subjects spending at least 15 min per day within 1 m of an operating microwave cooker or conventional cooker. This method could be extended to other appliances.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Radiat Prot DosimetryHome page
O. Bottauscio, M. Chiampi, G. Crotti, and M. Zucca
Influence of probe size on the measurement accuracy of non-uniform ELF magnetic fields
Radiat Prot Dosimetry, November 5, 2004; 111(4): 369 - 372.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.