Skip Navigation

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (1)
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Horowitz, Y.S.
Right arrow Articles by Hirning, C.R.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Horowitz, Y.S.
Right arrow Articles by Hirning, C.R.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Radiation Protection Dosimetry 66:97-100 (1996)
© 1996 Oxford University Press

Measurements of Beta Ray Spectra in CANDU Nuclear Generating Stations Using a Silicon Detector Coincidence Telescope

Y.S. Horowitz, Y. Weizman and C.R. Hirning

The measurement of beta ray spectra at various work locations inside nuclear generating stations operated by Ontario Hydro is described. The measurements were carried out using an advanced coincidence telescope spectrometer using silicon detectors only. The spectometer is capable of measuring electron energies over the range 60 keV-2500 keV with close to 100% coincidence efficiency. Photon rejection is carried out by requiring a coincidence between either two or three silicon detectors. Monte Carlo calculations were then used to estimate beta correction factors for the LiF:Mg,Ti elements used in the Ontario Hydro thermoluminescence dosemeters. Averaging over all the measured beta correction factors for the 'skin' chip (100 mg.cm-2) results in a value of 2.73 ± 0.77 and for the extremity dosemeter (240 mg.cm-2) an average value of 4.42 ± 1.17 is obtained. These values are 57% and 120% greater, respectively, than the current values used by Ontario Hydro. In addition, beta correction factors for nine representative spectra were calculated for 40 mg.cm-2 and 20 mg.cm-2 chips and the results demonstrate the benefits of decreased dosemeter thickness. The average value of the beta correction factor, as well as the spread in the beta correction factor, decreases dramatically from 4.80 ± 2.1 (240 mg.cm-2) to 1.29 ± 0.1 (20 mg.cm-2).


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.