Skip Navigation

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Kalmykov, L.
Right arrow Articles by Waligórski, M.P.R.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Kalmykov, L.
Right arrow Articles by Waligórski, M.P.R.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Radiation Protection Dosimetry 66:165-166 (1996)
© 1996 Oxford University Press

Evaluation of Effective Dose in Environmental Dosimetry Using Humanoid Phantoms Representing Different Ages and Sex, and LiF:Mg,Ti and LiF:Mg,Cu,P Detectors

L. Kalmykov, N. Pilipenko, P. Olko and M.P.R. Waligórski

Transition coefficients relating values of exposure in air, as read out with personal dosemeters, to effective dose from external exposure, have been evaluated. Four types of ICRP 23 heterogenic anthropomorphic phantoms, representing children of ages 1 y and of 5 y, Reference Woman and Reference Man, were exposed in an open space at the Chernobyl area and indoors, in brick and wooden dwellings. TL detectors: LiF:Mg, Ti and LiF:Mg,Cu,P were used inside the phantoms and in personal badges attached to the phantoms. In open space the ratio of the value of effective dose (E in µSv) to the value of exposure in air (X in mR) at 1 m above ground level was found to correlate linearly with phantom height, decreasing from 9.0 µSv.mR-1 (child, 1 y) to 6.1 µSv.mR-1 (Reference Man). The ratio of E and dose equivalent (H), as measured with personal dosemeters, was also found to correlate linearly with the ratio of the phantom height to its mass (range of E/H: 1.1-0.87). Indoors, values of E/X = 8.35 ± 0.31 µSv.mR-1 and E/H = 1.54 ± 0.04 were found for all phantoms and building materials studied. These results permit the height and weight of individuals to be included in the evaluation of effective dose incurred, e.g. over the Chernobyl area or from the radioactivity of building materials.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.