Skip Navigation

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (4)
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Waligórski, M.P.R.
Right arrow Articles by Kozak, K.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Waligórski, M.P.R.
Right arrow Articles by Kozak, K.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Radiation Protection Dosimetry 66:161-164 (1996)
© 1996 Oxford University Press

Environmental Radiometry Around Coal Mining Wastes Using MCP-N (LiF:Mg,Cu,P) Detectors and Gamma-Ray Spectrometry

M.P.R. Waligórski, K. Skarzynska, E. Zawisza, E. Ryba, M. Jasinska and K. Kozak

Natural gamma background dose rates 1 m above ground level were evaluated using MCP-N detectors (LiF:Mg,Cu,P, produced at INP Kraków) at over 30 points, and the natural radioactivity of samples of materials deposited at the Przezchlebie industrial stockpile gathered from some of these locations assessed off-site using gamma ray spectrometry. Measurements were made in late spring over different parts of the stockpile and the neighbouring terrain, and repeated after one year. Above-ground gamma dose rates correlated well with the activity of elements in the 232Th and 238U series, the 226Ra sub-series and 40K measured in the material samples. LiF:Mg,Cu,P (MCP-N) detectors are extremely convenient for use in environmental dosimetry as their stability and sensitivity allow field exposures to take no longer than two weeks, instead of three months required for LiF:Mg,Ti (TLD-100) detectors. This considerably speeds up measurements and may prevent theft or displacement of dosemeters in industrial conditions.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.