Radiation Protection Dosimetry 66:113-118 (1996)
© 1996 Oxford University Press

A New Extremity System and Performance at INEL

O.R. Perry, R.A. Tawil, K.J. Velbeck and J.E. Rotunda

The TLD extremity dosimetry system described herein incorporates the components necessary for personnel extremity monitoring to meet current and proposed requirements. Single and dual element TLD dosemeters, ranging in thicknesses from 20 to 100 mg.cm-2, and appropriate filtration comprise the extremity detectors which are uniquely identified by bar code labels. A dose algorithm used in conjunction with the dosemeters and TLD reader technology are capable of reporting shallow dose Hp(0.07) from betas, low and high energy photons using any combination of these dosemeters. Performance tests and results were obtained by the Idaho National Engineering Laboratory (INEL) Operational Dosimetry Unit in the evaluation of a single extremity dosemeter capable of simultaneously monitoring beta and high energy gamma. Four TL materials and two filter types were tested in various combinations to 137Cs photons, uranium slab, 90Sr/90Y, and 204TI beta, irradiations. An overview of the current INEL system dosemeter response, linearity, angular dependence, residual, and effects of physical damage to the dosemeter were tested. The results of these tests, presented here, lead to the preliminary conclusion that an extremity dosemeter can be constructed to monitor beta and high energy gamma radiation simultaneously.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.