Radiation Protection Dosimetry 56:71-76 (1994)
© 1994 Oxford University Press
Radon Reduction Techniques for Suspended Timber Floors and Pressure Field Extension Assessment of Hardcore Specifications
This paper comprises two case studies. The first describes a series of mitigation measures carried out in a small primary school fitted with a suspended timber floor. Radon levels had been successfully reduced but the floor subsequently collapsed due to an outbreak of dry-rot. The floor was replaced with a ground-bearing concrete slab fitted with a typical example of one of 200 or so sump-and-fan systems fitted by Cornwall County Council (CCC). Following consultation with the Building Research Establishment (BRE) a network of small bore pipes was fitted below the floor during construction to record variations in radon levels and pressures. The second case study describes the floor replacement at a second, similar school but with a permeable layer of material under the concrete slab and more pressure measurement points. The pressure measurements and their subsequent analysis are described and the performance of the two installations compared. Using BRE and CCC expertise, this technique is now being applied to a number of other replacement floors in order to assess pressure field extension in a variety of hardcore and blinding materials. It is hoped that by careful selection of hardcore and blinding specifications the increased pressure field extension obtained could result in new-build properties requiring fewer underfloor suction points and/or a reduction in fan power consumption with a greater degree of confidence of success than at present. The selection and design of suction systems to date has been on a very pragmatic basis.