Radiation Protection Dosimetry 33:55-58 (1990)
© 1990 Oxford University Press

The Dependence of Thermoluminescence Sensitivity Upon the Temperature of Irradiation in Meteorites and in Terrestrial Apatites

S.A. Durrani and I.J.M. Al-Khalifa

Measurements are reported on the TL sensitivity (i.e. TL glow output per unit ? ray test dose) of meteoritic specimens as well as terrestrial fluor- and chlor-apatites, as a function of irradiation temperature (Tirr). The irradiation temperatures ranged from liquid nitrogen to room temperature (77 - 293 K). A kilocurie 60Co ? ray source was used to deliver test doses of 400 Gy (40 krad) and 40 Gy (4 krad) to the various samples. A strong dependence of the TL sensitivity upon the temperature of irradiation was noted in the case of Kirin meteorite: its TL sensitivity (for the 493 K readout peak) decreased by a factor of ~2 when Tirr rose from liquid nitrogen (77 K) to dry ice in acetone (197 K) temperature, in the case of both 400 Gy and 40 Gy ? ray doses. In the case of the Antarctic meteorite specimen (ALHA 77182,13), there was a smaller effect, viz. a fall of ~14% in the TL output corresponding to dry ice and higher irradiating temperatures as compared to the 77 K irradiation. For chlorapatite, the TL sensitivity decreased monotonically with increasing temperature for both the 563 K and the 448 K glow peaks. For the fluorapatite, the effect of reduced response was observed only between -17 oC (256 K) and room temperature (293 K). Both the theoretical and the practical implications of these observations are discussed.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.