Skip Navigation


Radiation Protection Dosimetry Advance Access originally published online on August 17, 2009
Radiation Protection Dosimetry 2009 136(3):222-227; doi:10.1093/rpd/ncp160
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
136/3/222    most recent
ncp160v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Livingstone, R. S.
Right arrow Articles by Dinakaran, P. M.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Livingstone, R. S.
Right arrow Articles by Dinakaran, P. M.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author 2009. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oxfordjournals.org

Regional survey of CT dose indices in India

Roshan S. Livingstone* and Paul M. Dinakaran

Department of Radiology, Christian Medical College, Vellore, Tamil Nadu

* Corresponding author: roshanlivingstone{at}yahoo.com

Received May 19, 2009, amended July 23, 2009, accepted July 28, 2009

This study intends to evaluate the current level of computed tomography (CT) scanner doses installed in a region in India. In-site CT dose measurement was performed for 127 CT scanners in a region in India. CT dose index (CTDI) was measured using a 10 cm3 pencil ion chamber and 32-cm polymethyl methacrylate body phantom. The CT numbers and image noise were measured for the phantom using software available on each CT scanner. Of the 127 CT scanners, 13 were conventional, 53 helical single-section, 44 multidetector row CT (MDCT) and 17 refurbished machines. The mean-weighted CTDI (CTDIw) values calculated using standard exposure parameters for conventional, conventional refurbished, single-section helical scanner (SSHS), refurbished SSHS and MDCT scanners were 7.5, 6.53, 6.8, 6.6 and 7.04 mGy. Twenty-seven CT scanners had deranged CT numbers. Periodic quality assurance and regional dose surveys would be beneficial to set up regional reference levels in India.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.