Skip Navigation


Radiation Protection Dosimetry Advance Access originally published online on May 27, 2009
Radiation Protection Dosimetry 2009 135(1):64-68; doi:10.1093/rpd/ncp093
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
135/1/64    most recent
ncp093v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Abu-Khaled, Y. S.
Right arrow Articles by Haddadin, I. M.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Abu-Khaled, Y. S.
Right arrow Articles by Haddadin, I. M.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Published by Oxford University Press 2009

Radiation exposure from radioactive iodine 131I in and surrounding the patients' room

Y. S. Abu-Khaled1,*, A. S. Sandouqa2 and I. M. Haddadin3

1 Personal Dosimetry Laboratory, Royal Scientific Society, Amman, Jordan
2 Basic Sciences Department, Faculty of Engineering Technology, Al-Balqa' Applied University, Amman, Jordan
3 King Hussein Cancer Centre, Amman, Jordan

* Corresponding author: yahiasalem56{at}yahoo.com or yahia{at}rss.gov.jo

Received October 7, 2008, amended April 26, 2009, accepted April 29, 2009

The purpose of this study is to measure the environmental radiation exposure in and surrounding the room of patients treated with 131I. Absorbed dose rates were measured using thermoluminescence dosemeters, type TLD-200 (CaF2:Dy), in a continuous monitoring programme. It is found that the estimated annual shallow and deep dose rates are 226 and 175 mGy at the patient bed; 94 and 72 mGy in the bathroom; and 12 and 10 mGy at the visitor chair, respectively. The annual absorbed dose in the corridor is almost at the background level. It is found that the annual doses at the patient bed and in bathroom were above the limit for radiation workers, whereas the dose rate at the visitor chair was within the accepted limit for radiation workers and above the limit for the public.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.