Skip Navigation


Radiation Protection Dosimetry Advance Access originally published online on April 21, 2009
Radiation Protection Dosimetry 2009 134(3-4):152-158; doi:10.1093/rpd/ncp066
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
134/3-4/152    most recent
ncp066v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Kramer, G. H.
Right arrow Articles by Brown, J.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kramer, G. H.
Right arrow Articles by Brown, J.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author 2009. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oxfordjournals.org

A methodology for improving throughput using portal monitors

Gary H. Kramer1,*, Kevin Capello1, Barry Hauck1, Gerry Moodie1, Anthony DiNardo1, Linda Burns1, Albert Chiang1, Leonora Marro2 and Jason Brown3

1 National Internal Radiation Assessment Section, Radiation Protection Bureau, Health Canada, Ottawa, ON, Canada
2 Biostatistics Section, Population Studies Division, Health Canada, Ottawa, ON, Canada
3 Defense Research and Development Canada, Ottawa, ON, Canada

* Corresponding author: gary_h_kramer{at}hc-sc.gc.ca

Received March 26, 2009, amended March 26, 2009, accepted March 31, 2009

The National Internal Radiation Assessment Section (NIRAS), which operates the Canadian National Calibration Reference Centre for Bioassay and In Vivo Monitoring, has field deployable equipment for emergency response. A substantial part of this tool kit is a set of portal monitors that can be used to quickly screen people into the ‘uncontaminated’ and the ‘contaminated’. The former term refers to a person who has <60 kBq (empirical practical detection limit) of activation/fission products and the latter group is contaminated by that amount or more. Recent field work has shown that one type of the NIRAS's portal monitors can be alarmed at significant distances if the level of contamination is high enough. The other types, which do not initiate a count until either an infra-red beam is broken or a proximity detector is activated, do not alarm but their background will be raised and this causes other problems. This paper proposes a method of group monitoring to help speed up the process of screening a large number of potentially contaminated persons using portal monitors. In short, the group of potentially contaminated persons will be kept isolated from the portal stations. Depending on a real-time estimate of the percentage of contaminated persons in the crowd, groups of persons will be selected for screening. The hypergeometric distribution has been used to decide on the sampling group size with an expectation that 90% of the time no contaminated person will be present in the group. Once removed from the main waiting area, the group will be pre-screened and then, depending on the result, sent to the appropriate portal. It is anticipated that this will greatly speed up processing as it substantially reduces the transit time. Transits times have also been estimated in addition to the number of personnel required to run all of NIRAS‘s field deployable equipment.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.