Skip Navigation


Radiation Protection Dosimetry Advance Access originally published online on February 29, 2008
Radiation Protection Dosimetry 2008 130(3):300-308; doi:10.1093/rpd/ncn050
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
130/3/300    most recent
ncn050v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Smans, K.
Right arrow Articles by Bosmans, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Smans, K.
Right arrow Articles by Bosmans, H.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author 2008. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oxfordjournals.org

A study of the correlation between dose area product and effective dose in vascular radiology

K. Smans1,2,*, L. Struelens2, M.-T. Hoornaert3, F. Bleeser3, N. Buls4, D. Berus4, P. Clerinx4, F. Malchair5, F. Vanhavere2 and H. Bosmans1

1 Department of Radiology, University Hospitals of Leuven, Herestraat 49, 3000 Leuven, Belgium
2 SCK-CEN, Radiation Protection, Dosimetry and Calibration, Boeretang 200, 2400 Mol, Belgium
3 Department of Radiology, Centre Hospitalier Jolimont-Lobbes, Rue Ferrer 159, 7100 Haine Saint-Paul, Belgium
4 Department of Radiology, UZ Brussel, Laarbeeklaan 101, 1090 Brussels, Belgium
5 Department of Radiology, CHU-Lg – CHR-Lg, Rue Forgent 13, 4000 Liège, Belgium

* Corresponding author: kristien.smans{at}uz.kuleuven.ac.be

Received August 16, 2007, amended January 2, 2008, accepted January 10, 2005

The purpose of the multi-centre study was to assess dose area product (DAP) and effective dose of patients undergoing angiography of the lower limbs in Belgium and to investigate the correlation between DAP and effective dose. DAP values were measured in 12 centres and compared with the national diagnostic reference levels (DRLs). The effective dose (E) was estimated by multiplying the DAP with case-specific conversion coefficients (CCs) that were calculated with Monte Carlo software MCNP5. As a model for the patient, a mathematical hermaphrodite phantom was used. Calculations showed that tube configurations and extra Cu filtration have a large influence on these CCs. Due to the use of Cu filtration, effective dose can be twice as high for comparable DAP values. Also the use of an over-couch tube configuration is a disadvantage when compared with the under-couch tube configuration. For centres working under-couch without the use of extra Cu-filtration, the DAP values correlate very well with effective dose (Spearman's rank correlation {rho} ; = 0.97). For these conditions, general CCs between DAP and E were calculated. They were 0.083 mSv Gy–1 cm–2 (ICRP 60) and 0.065 mSv Gy–1 cm–2 (ICRP 103).


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.