Skip Navigation


Radiation Protection Dosimetry Advance Access originally published online on August 6, 2007
Radiation Protection Dosimetry 2008 128(3):309-311; doi:10.1093/rpd/ncm376
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
128/3/309    most recent
ncm376v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Love, G. J.
Right arrow Articles by Gibson, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Love, G. J.
Right arrow Articles by Gibson, S.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author 2007. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oxfordjournals.org

Use of the mini C-arm for wrist fractures—establishing a diagnostic reference level

Gavin J. Love*, Anand Pillai and Suzy Gibson

Glasgow Royal Infirmary, Glasgow, UK

* Corresponding author: gjlove{at}doctors.org.uk

Received April 12, 2007, amended May 31, 2007, accepted June 18, 2007

The establishment of diagnostic reference levels (DRLs) for all typical radiological examinations became mandatory following the implementation of the Ionising Radiations (Medical Exposure) Regulations Act 2000. At present, there are no national dosage guidelines in the UK regarding use of fluoroscopy in orthopaedic trauma. The increasing popularity of the mini C-arm image intensifier amongst surgeons has led to concerns regarding use of ionizing radiation by personnel who have not been trained in radiation protection. It is therefore essential to have formal protocols for use of the mini C-arm to comply with the law and to maintain safe clinical practice. It is attempted to provide dose data for wrist fracture manipulations that may be used as a basis for setting a DRL for this procedure. Screening times were recorded for 80 wrist manipulations in a fracture clinic setting using a mini C-arm image intensifier. A DRL was set using the third quartile value for screening time. The median screening time for wrist fractures was 20 s with a range from 1 to 177 s. The third quartile value for screening time was 34 s. This value can be used as a provisional DRL for wrist fracture manipulations. The DRL is a quantitative guide for the optimisation of radiological protection. IR(ME)R 2000 states that if it is consistently exceeded by an individual operator or a piece of equipment, investigation and remedial action must be taken. We recommend that trauma units establish their own local DRLs for common procedures as made mandatory by legislation.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer:
Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.