Skip Navigation


Radiation Protection Dosimetry Advance Access originally published online on June 16, 2007
Radiation Protection Dosimetry 2008 128(1):43-48; doi:10.1093/rpd/ncm232
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
128/1/43    most recent
ncm232v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (1)
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Bakshi, A. K.
Right arrow Articles by Kher, R. K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bakshi, A. K.
Right arrow Articles by Kher, R. K.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author 2007. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oxfordjournals.org

Estimation of bremsstrahlung photon energy in the environment of high-energy electron accelerator using CaSO4:Dy based TL dosemeter

A. K. Bakshi1,*, M. K. Nayak2, G. Haridas2, S. Chatterjee1 and R. K. Kher1

1 Radiological Physics & Advisory Division, Bhabha Atomic Research Centre, Mumbai 400 085, India
2 Health Physics Unit, Radiation Safety System Division, Bhabha Atomic Research Centre, Mumbai 400 085, India

* Corresponding author: akbakshi123{at}yahoo.com

Received January 31, 2007, amended March 19, 2007, accepted March 25, 2007

High-energy bremsstrahlung X rays constitute the major radiation hazard to working personnel around the high-energy electron accelerators. Thermoluminescent (TL) dosemeter system based on CaSO4:Dy Teflon disc used in the routine individual monitoring was used to estimate the bremsstruhlung photon energy at different locations of the experimental hall of 450-MeV synchrotron accelerator. The response of TL discs under different filter regions of the dosemeter system undergo change with photon energy due to the lack of build up and interaction of photon in the metal filters. This change in the response of the discs used to estimate the energy of the bremsstrauhlung photon in conjunction with suitable calibration curve generated using known photon energy from medical linear accelerator. The photon energies estimated were in the range 1–4 MeV, depending on the locations.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.