Skip Navigation


Radiation Protection Dosimetry Advance Access originally published online on July 6, 2006
Radiation Protection Dosimetry 2007 123(1):3-14; doi:10.1093/rpd/ncl074
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
123/1/3    most recent
ncl074v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (1)
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Monk, S. D.
Right arrow Articles by Joyce, M. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Monk, S. D.
Right arrow Articles by Joyce, M. J.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author 2006. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oxfordjournals.org

The design of a portable cosmic ray three-band neutron detector

S. D. Monk and M. J. Joyce*

Nuclear and Biomedical Engineering Research Group, Department of Engineering, Lancaster University, Lancaster LA1 4YR, UK

* Corresponding author: m.joyce{at}lancaster.ac.uk

Received April 2, 2003, amended November 19, 2003, accepted December 22, 2003


   Abstract

The design of a portable three-band cosmic-ray neutron detector is reported in this article. This instrument has been designed to characterise cosmic ray neutron fields in the upper atmosphere and in cosmic reference field facilities. The design utilises a spherical moderator with a layer of spallation material covering a central 3He proportional counter. The instrument incorporates twelve lithium-coated diodes, six on the outside of the polyethylene layer and six placed within the structure. The dimensions, materials and arrangement of these in the instrument have been optimised with MCNPX to provide a compromise between the requirements of portability and spectral response.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer:
Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.