Skip Navigation


Radiation Protection Dosimetry Advance Access originally published online on January 25, 2006
Radiation Protection Dosimetry 2006 121(2):92-98; doi:10.1093/rpd/nck003
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
121/2/92    most recent
nck003v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Nair, H. G.
Right arrow Articles by Sharma, D. N.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Nair, H. G.
Right arrow Articles by Sharma, D. N.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author 2006. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oxfordjournals.org

Determination of dose-build-up thickness for absorbed dose measurement in high energy electron-photon radiation at electron storage rings

Haridas G. Nair*, Vipin Dev1, M. K. Nayak1, K. K. Thakkar1, P. K. Sarkar2 and D. N. Sharma2

1 Health Physics Unit, Centre for Advanced Technology, Indore 452 013, India
2 Radiation Safety Systems Division, Bhabha Atomic Research Centre, Mumbai 400 085, India

* Corresponding author: haridas{at}cat.ernet.in

Received October 7, 2005, amended December 9, 2005, accepted December 20, 2005


   Abstract

Radiation field during accidental electron beam loss near electron storage rings comprises of high-energy electrons and bremsstrahlung photons. Due to high-energy nature of the radiation, the absorbed dose is expected to build up with depth of the body of an exposed worker and hence absorbed dose measurements in 30 cm water/tissue equivalent phantom is essential. Carrying out the measurements with in such phantoms is not practically feasible for routine applications and hence the use of an equivalent solid material around the dosemeters would be convenient. Monte Carlo calculations have been carried out in order to determine the dose-build-up thickness required in copper and lead, corresponding to the maximum absorbed within 30 cm depth of water in such radiation fields. Equivalent build-up thickness calculated for a case was verified by measurement using an ion chamber detector. The results are found to be in agreement within ±20%.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Radiat Prot DosimetryHome page
M. Kumar, R. K. Kher, G. Sahni, and K. Chhokra
Studies on the response of the TLD badge for high-energy photons
Radiat Prot Dosimetry, February 1, 2008; 128(3): 266 - 273.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.