Skip Navigation


Radiation Protection Dosimetry Advance Access originally published online on July 28, 2006
Radiation Protection Dosimetry 2006 121(1):70-79; doi:10.1093/rpd/ncl097
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
121/1/70    most recent
ncl097v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Dirkx, M. L. P.
Right arrow Articles by Heijmen, B. J. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Dirkx, M. L. P.
Right arrow Articles by Heijmen, B. J. M.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author 2006. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oxfordjournals.org

Improvement of radiotherapy treatment delivery accuracy using an electronic portal imaging device

M. L. P. Dirkx*, J. C. J. de Boer and B. J. M. Heijmen

Department of Radiation Oncology, Division of Medical Physics, Erasmus MC-Daniel den Hoed Cancer Center, Groene Hilledijk 301, 3075 EA Rotterdam, The Netherlands

* Corresponding author: m.dirkx{at}erasmusmc.nl


   Abstract

Reliable application of advanced external beam techniques for the treatment of patients with cancer, such as intensity modulated radiotherapy, requires an adequate quality assurance programme for the verification of the dose delivery. Accurate patient positioning is mandatory because of the steep dose gradients outside the tumour volume. Owing to the increased complexity of the treatment planning and delivery techniques, verification of the dose delivery before and during the actual patient treatment is equally important. For this purpose, a quality assurance programme has been established in our clinic that is primarily based on measurements with electronic portal imaging devices. To minimise systematic set-up errors, the patient positioning is measured in the first few treatment fractions and a set-up correction is applied in the subsequent ones. Before the first treatment fraction, portal dose measurements are performed for each treatment field with the electronic portal imaging device to verify that the planned fluence distribution is correctly delivered at the treatment unit. Dosimetric measurements are also performed during patient treatment to derive the actually delivered fluence maps. By combining this information with knowledge on the patient set-up, the delivered 3-D dose distribution to both the tumour and sensitive organs may be assessed. However, for the highest accuracy, exact knowledge on the (internal) patient geometry during treatment, e.g. using a cone-beam CT, is required.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer:
Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.