Skip Navigation

Radiation Protection Dosimetry 2006 121(1):40-51; doi:10.1093/rpd/ncl152
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Etherington, G
Right arrow Articles by Blanchardon, E
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Etherington, G
Right arrow Articles by Blanchardon, E
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

George Etherington, Centre for Radiation, Chemical and Environmental Hazards. Crown Copyright 2006. Reproduced with the permission of the Controller of Her Majesty's Stationery Office

Uncertainties in doses from intakes of radionuclides assessed from monitoring measurements

G Etherington1,*, A Birchall1, M Puncher1, A Molokanov2,3 and E Blanchardon3

1 Health Protection Agency, Centre for Radiation Chemical and Environmental Hazards, Radiation Protection Division, Chilton, Didcot, Oxon OX11 0RQ, UK
2 The State Research Center, Institute of Biophysics, 123182, Moscow Zhivopisnaja, 46, Russia
3 Institut de Radioprotection et de Sûreté Nucléaire, Direction de la RadioProtection de l'Homme, IRSN, BP 17, F-92262 Fontenay-aux-Roses Cedex, France

* Corresponding author: george.etherington{at}hpa.org.uk


   Abstract

The evaluation of uncertainties in doses from intakes of radionuclides is one of the most difficult problems in internal dosimetry. In this paper, the process of assessing internal doses from monitoring measurements is reviewed and the major sources of uncertainty are discussed. Methods developed independently at HPA and at IRSN for the determination of uncertainties in internal doses assessed from monitoring measurements are described. Both use a Monte Carlo simulation approach. Results are described for three illustrative examples. An alternative method developed at the Los Alamos National Laboratory that uses Bayesian statistical methods is also described briefly.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Radiat Prot DosimetryHome page
G. Miller, L. Bertelli, T. Little, and R. A. Guilmette
INTERNAL DOSIMETRY VERIFICATION AND VALIDATION DATABASE
Radiat Prot Dosimetry, March 6, 2008; (2008) ncm470v1.
[Abstract] [Full Text] [PDF]



Disclaimer:
Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.