Skip Navigation

Radiation Protection Dosimetry 2006 120(1-4):289-292; doi:10.1093/rpd/nci520
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (2)
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Alves, J. G.
Right arrow Articles by Santos, L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Alves, J. G.
Right arrow Articles by Santos, L.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author 2006. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oxfordjournals.org

Long-term stability of a TLD-based individual monitoring system

J. G. Alves*, J. N. Abrantes, O. Margo, S. Rangel and L. Santos

Instituto Tecnológico e Nuclear, Departamento de Protecção Radiológica e Segurança Nuclear, Estrada Nacional 10, 2686-953 Sacavém, Portugal

* Corresponding author: jgalves{at}itn.pt

The thermoluminescence dosemeter (TLD) system at the Individual Monitoring Service (IMS) of the Nuclear Technology Institute (ITN) at the Radiological Protection and Nuclear Safety Department (DPRSN) comprises two 6600 Harshaw readers and the Harshaw 8814 TL card and the holder containing two LiF:Mg,Ti (TLD-100) dosemeters for the evaluation of Hp(10) and Hp(0.07). The readers are calibrated on a monthly basis and as part of the quality assurance programme implemented at the IMS a set of dosemeters is issued monthly to the DPRSN's Standard Dosimetry Laboratory for linearity measurements. The results obtained since November 2001 are presented. Fading and sensitivity change experiments are carried out every month covering 8 week periods so that enough time is given to simulate issuing, integrating and receiving times and respective delays. A set of 96 dosemeters organised in eight subsets of 12 are used. In each subset, four dosemeters are irradiated and stored at room temperature (RT), four are not irradiated at all and the last four are irradiated after storage. The 12 dosemeters of each subset are readout at the same time, one per week, covering the 8 week period. The results from the sets irradiated and stored at different periods allowed for the evaluation of fading and sensitivity changes experienced over the whole monitoring period and respective preparation time and readout delays. Time evolution charts of the reader calibration factors, of the linearity parameters and of the evolution of the integrated area in the region of dosimetric interest with storage at RT were obtained. This paper aims to quantify the long-term stability of the TLD system in use at the IMS.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.