Skip Navigation


Radiation Protection Dosimetry Advance Access originally published online on April 27, 2006
Radiation Protection Dosimetry 2006 120(1-4):278-282; doi:10.1093/rpd/nci565
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
120/1-4/278    most recent
nci565v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (2)
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Fantuzzi, E.
Right arrow Articles by Uleri, G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Fantuzzi, E.
Right arrow Articles by Uleri, G.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author 2006. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oxfordjournals.org

The implementation in routine of the ENEA new personal photon dosemeter

E. Fantuzzi1,*, F. Mariotti2, B. Morelli1 and G. Uleri1

1 ENEA, Radiation Protection Institute, via dei Colli, 16-40136 Bologna, Italy
2 DIENCA, Department of Energy, Nuclear and Environmental Engineering, University of Bologna, via dei Colli, 16-40136 Bologna, Italy

* Corresponding author: fantuzzi{at}bologna.enea.it

The ENEA photon dosemeter, introduced in 1995, consisting of two differently filtrated LiF(Mg,Cu,P) detectors, has been modified recently. The ABS (acrylonitrile butadiene styrene) plastic support has been replaced by a new aluminium card supporting the same two detectors (LiF(Mg,Cu,P) GR200). The new card, fully developed at the ENEA-Radiation Protection Institute (which is going to be patented), can now be processed through a Harshaw Model 6600 Automated TLD Reader, a hot gas reader. This paper reports the results of the individual calibration of ~60,000 LiF(Mg,Cu,P) GR200 detectors inserted on the new aluminium cards. Before the implementation in routine of the new cards, the reader has been characterised. Steps and tests to be made to use the card in routine (i.e. reader stability, linearity, reproducibility, etc.) are reported. The whole dosimetric system now combines the very good performances of the Harshaw Model 6600 reader and that of LiF(Mg,Cu,P) thermoluminescent material.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Radiat Prot DosimetryHome page
A. Romanyukha, D. King, and L. A. Benevides
Effect of background radiation on the lower limit of detection for extended dosemeter issue periods
Radiat Prot Dosimetry, August 1, 2008; 131(2): 180 - 187.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.