Skip Navigation


Radiation Protection Dosimetry Advance Access originally published online on February 23, 2006
Radiation Protection Dosimetry 2006 118(4):431-439; doi:10.1093/rpd/nci379
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
118/4/431    most recent
nci379v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (1)
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Sharma, S.
Right arrow Articles by Ebadi, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Sharma, S.
Right arrow Articles by Ebadi, M.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author 2006. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oxfordjournals.org

Radiation safety and quality control in the cyclotron laboratory

Sushil Sharma*, Gregory Krause and Manuchair Ebadi

Positron Imaging Research Laboratory, Center of Excellence in Neurosciences, University of North Dakota, School of Medicine and Health Sciences, 501 North Columbia Road, Grand Forks, ND 58203, USA

* Corresponding author: skumar{at}medicine.nodak.edu

Received July 8, 2005, amended November 24, 2005, accepted December 5, 2005

Radiation safety was determined to maintain quality control in the cyclotron laboratory. Based on the results of 438 runs in the Faraday cup (20 µA for 10 min), 20 runs on 18O–water target (40 µA for 2 h) and 10 runs on 18O–gas targets (30 µA for 45 min), we have established that occupationally exposed workers remain 10 ± 5 times below federal regulatory limits (FRLs) in the cyclotron vault, 30 ± 8 times below FRL in the radiochemistry laboratory and 200 ± 10 times below the FRL outside the cyclotron laboratory during beam operation. (The FRL for unrestricted area are <20 µSv in 1 h.) The non-occupationally exposed workers serving in offices in the vicinity of the cyclotron vault within 100 m distance remained 200 times below the FRL irrespective of beam being on or off, suggesting that routine beam operation of 40 µA for 2 h once a day during office hours is safe provided quality control and system performance measures as discussed in this report are strictly maintained.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.