Skip Navigation


Radiation Protection Dosimetry Advance Access originally published online on February 3, 2006
Radiation Protection Dosimetry 2005 117(1-3):277-282; doi:10.1093/rpd/nci739
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
117/1-3/277    most recent
nci739v2
nci739v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Zoetelief, J.
Right arrow Articles by Bosmans, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Zoetelief, J.
Right arrow Articles by Bosmans, H.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author 2006. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oxfordjournals.org

Quality control of equipment used in digital and interventional radiology

J. Zoetelief1,*, R. T. M. van Soldt1, I. I. Suliman1, J. T. M. Jansen1 and H. Bosmans2

1 Delft University of Technology, IRI, Mekelweg 15, 2629 JB Delft, The Netherlands
2 Leuven University Centre for Medical Physics in Radiology, University Hospitals of the Catholic University of Leuven, Belgium

* Corresponding author: j.zoetelief{at}iri.tudelft.nl

Digital and interventional radiology are increasingly important areas of radiology. Quality control (QC) of such equipment is of particular importance to avoid unnecessary high doses and to help to achieve good image quality. Within the DIMOND III project, equipment requirements and specifications for digital and interventional radiology have been formulated. A protocol for QC tests has been drafted based on various national and international recommendations. Tests are included for various parts of the imaging chain, i.e. X-ray tube and generator, X-ray tube control system, laser printer and display station, and image quality and patient dose. Preliminary tolerance levels have been set for the various tests, after initial measurements. To check the suitability of QC tests and stated tolerance levels, measurements were made at the University Hospital Gasthuisberg in Leuven for equipment used for paediatric radiology and a unit used for chest examinations. The results of the various tests are reported.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Radiat Prot DosimetryHome page
R. Padovani, A. Trianni, C. Bokou, H. Bosmans, J. Jankowski, S. Kottou, K. Kepler, J. Malone, V. Tsapaki, D. Salat, et al.
Survey on performance assessment of cardiac angiography systems
Radiat Prot Dosimetry, March 1, 2008; 129(1-3): 108 - 111.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.