Skip Navigation


Radiation Protection Dosimetry Advance Access originally published online on February 3, 2006
Radiation Protection Dosimetry 2005 117(1-3):107-110; doi:10.1093/rpd/nci763
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
117/1-3/107    most recent
nci763v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Goni, H.
Right arrow Articles by Georgiou, Ev.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Goni, H.
Right arrow Articles by Georgiou, Ev.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author 2006. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oxfordjournals.org

Investigation of occupational radiation exposure during interventional cardiac catheterisations performed via radial artery

H. Goni1,*, D. Papadopoulou2, Em. Yakoumakis2, N. Stratigis3, J. Benos3, V. Siriopoulou3, Tr. Makri2,4 and Ev. Georgiou2

1 Department of Radiology, ‘Laiko’ Per. General Hospital, Ag. Thoma 17, Goudi, 11527 Athens, Greece
2 Department of Medical Physics, Medical School, University of Athens, 75 Mikras Asias, 11527 Athens, Greece
3 Department of Interventional Radiology, ‘Laiko’ Per. General Hospital, Ag. Thoma 17, Goudi, 11527 Athens, Greece
4 Department of Radiology, ‘Aghia Sofia’ Children's Hospital, 1 Thivon and Levadias Street, Athens 11527, Greece

* Corresponding author: helen.gonis{at}freemail.gr

The purpose of this study was to determine the thyroid, sternum and hand radiation doses of radiologists who perform angiographies and angioplasties via the radial artery. Staff radiation dose was estimated for 21 cardiac interventional catheterisations. Thermoluminescence dosemeters (TLDs) were used to determine radiation dose for each procedure at the right and left wrist, at the sternum and the thyroid. A dose area product (DAP) meter was also attached to give a direct value in Gy cm2 for each procedure. Staff radiation doses varied between 34 and 235 µGy per procedure at the left wrist, 28 and 172 µGy at the right wrist, 16 and 106 µGy at the level of the thyroid and 16 and 154 µGy at the level of the sternum. The DAP values varied between 25 and 167 Gy cm2. Radiation doses in this study are comparable to those reported in previous studies. Moreover, good correlation was found between the DAP values and the occupational dose measured with TLDs.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer:
Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.