Skip Navigation


Radiation Protection Dosimetry Advance Access originally published online on April 7, 2005
Radiation Protection Dosimetry 2005 113(4):392-395; doi:10.1093/rpd/nch488
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
113/4/392    most recent
nch488v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Sæther, H. K.
Right arrow Articles by Wøhni, T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Sæther, H. K.
Right arrow Articles by Wøhni, T.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author 2005. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oupjournals.org

Measurements of finger doses in x-ray guided surgery, nuclear medicine and research

H. K. Sæther*, T.-M. Davidson, A. Widmark and T. Wøhni

Norwegian Radiation Protection Authority, P.O. Box 55, N-1332 Østerås, Norway

* Corresponding author: hilde.kjernlie.sather{at}nrpa.no

Received January 1, 2005, amended February 25, 2005, accepted March 14, 2005

The Norwegian Radiation Protection Authority has performed measurements of finger doses to nuclear medicine staff exposed to 99Tcm, researchers handling 32P, surgeons performing X-ray guided orthopaedic surgery and surgeons and radiologists performing X-ray guided endovascular treatment of abdominal aortic aneurysms (AAA). Calibrations were done with X-ray qualities N-40, N-60 and N-300 and with the beta source 90Sr + 90Y. Annual doses were estimated for the nuclear medicine staff and the orthopaedic surgeons. The mean annual finger dose to nuclear medicine staff exposed to 99Tcm was estimated to be 18.8 mSv, and the mean annual finger dose to surgeons performing X-ray guided orthopaedic surgery was 13.7 mSv. The surgeons and radiologists performing X-ray guided endovascular treatment of AAA received a mean finger dose of 0.35 mSv per treatment. The majority of researchers handling 32P received no finger dose at all, and the maximum reading was 1.65 mSv. All occupational groups received finger doses well below the annual finger dose limit of 500 mSv.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Radiat Prot DosimetryHome page
M. Wrzesien, J. Olszewski, and J. Jankowski
Hand exposure to ionising radiation of nuclear medicine workers
Radiat Prot Dosimetry, July 1, 2008; 130(3): 325 - 330.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.