Skip Navigation


Radiation Protection Dosimetry Advance Access originally published online on February 9, 2005
Radiation Protection Dosimetry 2005 113(3):251-265; doi:10.1093/rpd/nch461
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
113/3/251    most recent
nch461v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Ribeiro, F. B.
Right arrow Articles by Strobino, E. F.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ribeiro, F. B.
Right arrow Articles by Strobino, E. F.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author 2005. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oupjournals.org

A least squares procedure for calculating the calibration constants of a portable gamma-ray spectrometer

F. B. Ribeiro*, D. U. Carlos, F. Y. Hiodo and E. F. Strobino

Departamento de Geofísica, Instituto de Astronomia, Geofísica e Ciências Atmosféricas da Universidade de São Paulo, Rua do Matão, 1226 Butantã, 05508-090 São Paulo, SP, Brasil

* Corresponding author: brenha{at}iag.usp.br

Received November 26 2004, amended and accepted January 10 2005

In this study, a least squares procedure for calculating the calibration constants of a portable gamma-ray spectrometer using the general inverse matrix method is presented. The procedure weights the model equations fitting to the calibration data, taking into account the variances in the counting rates and in the radioactive standard concentrations. The application of the described procedure is illustrated by calibrating twice the same gamma-ray spectrometer, with two independent data sets collected ~18 months apart in the same calibration facility.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.