Radiation Protection Dosimetry Vol. 112, No. 1 © Oxford University Press 2004; all rights reserved
A catalogue of dosemeters and dosimetric services within European update
1 CIEMAT-Dosimetry Unit, Avda. Complutense 22, 28040 Madrid, Spain
2 ENEA-IRP, 40136 Bologna, Italy
3 RPII, Dublin 14, Ireland
4 NRG Radiation and Environment, Utrechtseweg 310, Postbus 9034, 6800 AS Arnhem, Netherlands
5 SSI, Stockholm, Sweden
6 Institute of Nuclear Physics, Radzikowskiego 152, PL 31-342 Krakow, Poland
7 Paul Scherrer Institute, CH-5232 Villigen PSI, Switzerland
* Corresponding author: pawel.olko{at}ifj.edu.pl
The catalogue of dosemeters and dosimetric services within the European Union (EU) Member States and Switzerland that was issued by EURADOS in the year 2000 has been updated and extended with information on dosimetric services in the new EU Member States and Bulgaria, Croatia, Romania, Serbia and Montenegro, and Ukraine. The total number of dosimetric services in these European countries is now estimated to be about 200. The present catalogue is based on information collected from 90 European dosimetric services, among which 34 questionnaires from 32 services were obtained over the years 20012004 for the first time. This article assesses and updates the present use of personal dosemeters and the extent to which occupationally exposed persons in Europe are monitored with dosemeters able to measure the operational quantitypersonal dose equivalent, HP(d). The perspective of joining EU by the new countries accelerated the implementation of the EU Basic Safety Standard Directive to their national regulations. As a result, all newly investigated services reported their ability to measure HP(d). The catalogue provides information on the dosemeters, dose calculation and background subtraction algorithms, calibration methods, energy and angular response, and performance.
![]()
CiteULike
Connotea
Del.icio.us What's this?
This article has been cited by other articles:
![]() |
J.-M. Bordy, J. Daures, I. Clairand, M. Denoziere, L. Donadille, F. d'Errico, J. Gouriou, C. Itie, and L. Struelens EVALUATION OF THE CALIBRATION PROCEDURE OF ACTIVE PERSONAL DOSEMETERS FOR INTERVENTIONAL RADIOLOGY Radiat Prot Dosimetry, August 30, 2008; (2008) ncn225v1. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. W. Schultz and J. Zoetelief Estimating effective dose for a cardiac catheterisation procedure with single or double personal dosemeters Radiat Prot Dosimetry, May 1, 2006; 118(2): 196 - 204. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Stadtmann, M. Figel, V. Kamenopoulou, D. Kluszczynski, H. Roed, and J. Van Dijk Quality control and reliability of reported doses Radiat Prot Dosimetry, November 22, 2004; 112(1): 169 - 189. [Abstract] [Full Text] [PDF] |
||||
