Skip Navigation

Radiation Protection Dosimetry 2004 112(1):3-44; doi:10.1093/rpd/nch282
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (6)
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Fantuzzi, E.
Right arrow Articles by Vartiainen, E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Fantuzzi, E.
Right arrow Articles by Vartiainen, E.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Radiation Protection Dosimetry Vol. 112, No. 1 © Oxford University Press 2004; all rights reserved

Implementation of standards for individual monitoring in Europe

E. Fantuzzi1,*, J. G. Alves2, P. Ambrosi3, H. Janzekovic4 and E. Vartiainen5

1 ENEA, Radiation Protection Institute, via dei Colli 16–40136 Bologna, Italy
2 Instituto Tecnológico e Nuclear, Departamento de Protecção Radiológica e Segurança Nuclear, Estrada Nacional 10, 2686-953 Sacavém, Portugal
3 PTB, Physikalisch-Technische Bundesanstalt, PO Box 3345, D-38116 Braunschweig, Germany
4 Slovenian Nuclear Safety Administration, Zelezna cesta 16, PO box 5759-1001 Ljubljana, Slovenia
5 STUK, Radiation and Nuclear Safety Authority, PO Box 14, FIN 00881 Helsinki, Finland

* Corresponding author: fantuzzi{at}bologna.enea.it

A large number of standards are available for radiation protection and individual monitoring purposes. They are published by various organisations, international and national. Moreover, the increasing policy of ‘Quality’ applied to individual monitoring requires the implementation of standards on Quality Assurance (QA) both in technical and management aspects of a dosimetric service. Implementation of standards is not mandatory; therefore, varying degrees of implementation can be found in different European countries. However, for a number of good reasons, a degree of harmonisation within the European Union (EU) of the requirements and procedures for individual monitoring would be desirable. Harmonisation as applied to dosimetric services does not mean that they should all follow exactly the same procedures, but that they should aim to meet the same general requirements, and their results should be comparable.

This article aims to compile information on the use of all standards applied within individual monitoring practices, be it on the calibration of dosemeters or on the QA procedures to be applied to the overall dose evaluation process.

Both ‘technical standards’ and ‘quality standards’ will be discussed. A list of documents of relevance to subjects such as recommendations and requirements in the field of individual monitoring, whose application could help in the harmonisation of procedures, will also be given.

As it is agreed that implementation of quality standards is a relevant framework within which harmonisation can be achieved, guidance on the implementation of quality standards in a dosimetric service is given.

Accreditation and approval of dosimetric services will be of relevance in the process of harmonisation of individual monitoring within the EU. In this article, a discussion of various procedures and the meaning of both forms of recognition is also provided. Although most of the text applies to the monitoring of internal and external exposure to ionising radiation, the emphasis of this practical guidance is on monitoring for external radiation with passive dosemeters.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
JOURNAL OF THE ICRUHome page
REFERENCES
J. ICRU, December 1, 2006; 6(2): 47 - 50.
[Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
J. W. E. van Dijk
On the assessment of the performance of personal dosemeters and individual monitoring services
Radiat Prot Dosimetry, September 1, 2006; 120(1-4): 250 - 258.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
H. Stadtmann, M. Figel, V. Kamenopoulou, D. Kluszczynski, H. Roed, and J. Van Dijk
Quality control and reliability of reported doses
Radiat Prot Dosimetry, November 22, 2004; 112(1): 169 - 189.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.