Skip Navigation

Radiation Protection Dosimetry 2004 111(1):65-71; doi:10.1093/rpd/nch362
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Ohnishi, S.
Right arrow Articles by Saito, K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ohnishi, S.
Right arrow Articles by Saito, K.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Radiation Protection Dosimetry Vol. 111, No. 1 © Oxford University Press 2004; all rights reserved

Analysis of localised dose distribution in human body by Monte Carlo code system for photon irradiation

S. Ohnishi1,*, N. Odano1, N. Nariyama2 and K. Saito3

1 National Maritime Research Institute, 6-38-1 Shinkawa, Mitaka-si, Tokyo, 181-0004, Japan
2 Japan Synchrotoron Radiation Research Institute, Kouto 1-1-1, Mikazuki Sayo, Hyogo 679-5198, Japan
3 Japan Atomic Energy Research Institute, 2-4 Shirakatashirane, Tokai-mura, Naka-gun, Ibaraki, 319-1195, Japan

* Corresponding author: sohnishi{at}nmri.go.jp

In usual personal dosimetry, whole body irradiation is assumed. However, the opportunity of partial irradiation is increasing and the tendencies of protection quantities caused under those irradiation conditions are different. The code system has been developed and effective dose and organ absorbed doses have been calculated in the case of horizontal narrow photon beam irradiated from various directions at three representative body sections, 40, 50 and 60 cm originating from the top of the head. This work covers 24 beam directions, each 15° angle ranging from 0° to 345°, three energy levels, 45 keV, 90 keV and 1.25 MeV, and three beam diameters of 1, 2 and 4 cm. These results show that the beam injected from diagonally front or other specific direction causes peak dose in the case of partial irradiation.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.