Skip Navigation

Radiation Protection Dosimetry 2004 111(1):21-25; doi:10.1093/rpd/nch354
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (2)
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Alves, J. G.
Right arrow Articles by Santos, L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Alves, J. G.
Right arrow Articles by Santos, L.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Radiation Protection Dosimetry Vol. 111, No. 1 © Oxford University Press 2004; all rights reserved

Study on quality control parameters of a TLD system for individual monitoring

J. G. Alves*, R. Montezuma, O. Margo and L. Santos

Instituto Tecnológico e Nuclear, Departamento de Protecção Radiológica e Segurança Nuclear, Estrada Nacional 10, 2686-953 Sacavém, Portugal

* Corresponding author: jgalves{at}itn.mces.pt

This work intends to identify and follow up quality control parameters important for the general improvement of our thermoluminescence dosemeter (TLD) system for Individual Monitoring that is currently preparing its accreditation according to the EN ISO/IEC 17025 Standard. A retrospective analysis of the readers' start-up tests revealed an eventual variation of parameters, like the high voltage, which may affect the light collecting system, and hence the TL dose results. This was investigated and although the high voltage requires a careful look, the stability and reproducibility of the TLD system was ascertained by the results of quality control procedures. As a consequence of this work, the start-up procedure was modified and the warning levels used for the start-up daily tests of the readers were derived from a more realistic approach.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Radiat Prot DosimetryHome page
J. G. Alves, J. N. Abrantes, O. Margo, S. Rangel, and L. Santos
Long-term stability of a TLD-based individual monitoring system
Radiat Prot Dosimetry, September 1, 2006; 120(1-4): 289 - 292.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
J. G. Alves, J. N. Abrantes, and S. Rangel
Implications of the high voltage induced variation on TL readings
Radiat Prot Dosimetry, September 1, 2006; 120(1-4): 293 - 297.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.