Skip Navigation

Radiation Protection Dosimetry 2004 111(1):13-15; doi:10.1093/rpd/nch352
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (5)
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Caldas, L. V.E.
Right arrow Articles by Teixeira, M. I.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Caldas, L. V.E.
Right arrow Articles by Teixeira, M. I.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Radiation Protection Dosimetry Vol. 111, No. 1 © Oxford University Press 2004; all rights reserved

Coloured glasses for high dose dosimetry using the thermoluminescent technique

Linda V.E. Caldas* and Maria Inês Teixeira

Instituto de Pesquisas Energéticas e Nucleares, Comissão Nacional de Energia Nuclear, C.P. 11049, 05422-970, São Paulo, SP, Brazil

* Corresponding author: lcaldas{at}ipen.br

Coloured glasses produced commercially by Cebracê, São Paulo, were analysed by the thermoluminescent (TL) method, to verify the possibility of their use as high-dose dosemeters or irradiation indicators in industrial areas, due to their easy handling and their low cost. The samples were exposed to different radiation doses, using the Gamma-Cell 220 system (60Co) of IPEN. The TL emission curves presented main peaks at 135, 150 and 145°C in the bronze, brown and green glass samples, respectively. Calibration curves were obtained for the glasses between 50 Gy and 360 kGy. Reproducibility of TL response and the lower detection doses were determined for each kind of glass. All tested glasses showed their usefulness as irradiation indicators and as high-dose dosemeters.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.