Skip Navigation

Radiation Protection Dosimetry 2004 111(1):105-110; doi:10.1093/rpd/nch370
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (1)
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Nogueira, M. S.
Right arrow Articles by Campos, L. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Nogueira, M. S.
Right arrow Articles by Campos, L. L.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Radiation Protection Dosimetry Vol. 111, No. 1 © Oxford University Press 2004; all rights reserved

(HP)Ge Measurement of spectra for diagnostic X-Ray beams

M. S. Nogueira1,*, H. C. Mota2 and L. L. Campos3

1 Centro de Desenvolvimento da Tecnologia Nuclear, R. Mário Werneck, S/N, 30123-970, Belo Horizonte, MG, Brazil
2 Instituto de Radioproteção e Dosimetria, Av. Salvador Allende S/N, 22780-160 Rio de Janeiro, RJ, Brazil
3 Instituto de Pesquisas Energéticas e Nucleares, Av. Prof. Lineu Prestes, 2242 05505-000 São Paulo, SP, Brazil

* Corresponding author: mnogue{at}cdtn.br

The X-ray spectra applied in diagnostic radiology to the energy range between 50 and 125 kVp, were experimentally determined using a high-purity germanium detector, (HP)Ge, coupled to a multichannel analyser. A simple stripping procedure was implemented, according to that described by Seelentag and Panzer, to correct the pulse height distribution and then to determine the photon spectra. The measurements were performed for those conditions where the X-ray beam is transmitted through Pb filters 0.2–0.7 mm thick. It was necessary to estimate the effective dose in the same way that it is done for radiology diagnosis room shielding projects. The spectra were also determined to the X-ray qualities recommended by the IEC for primary diagnostic X-ray and for X-ray beams attenuated by aluminium filters 2.5–42.5 mm thick. The spectra obtained were compared with data derived from the literature presenting good agreement.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.