Energy dependence of new thermoluminescent detectors in terms of Hp10 values
The aim of this work was to determine energy dependence characteristics in terms of values of the personal dose equivalant, Hp(10). The following types of thermoluminescent detectors (TLDs) were investigated: (a) two new types based on lithium borate Li2B407:Cu,In and Li2B407:Cu,In,Ag; (b) two types based on the highly sensitive material LiF:Mg,Cu,P, TLD-700H and GR 200A; (c) two well-known types of LiF:Mg,Ti detectors, TLD-100 and TLD-700 and (d) highly sensitive Al203:C detectors. TLDs previously calibrated with 137Cs gamma rays were simultaneously irradiated with X ray beams in the range of mean energies between 33 and 116 keV. The irradiations were performed with detectors in polymethyl methacrylate (PMMA) holders placed on a 30 cm x 30 cm x 15 cm water phantom with PMMA walls (ISO phantom). Measured energy responses were compared with calculated data for Hp(10) values. The results confirmed the satisfactory tissue equivalent characteristics of all investigated TLDs except Al203:C, which (due to its large energy dependence) is suitable for personal dosimetry only with an appropriate filter.
![]()
CiteULike
Connotea
Del.icio.us What's this?
This article has been cited by other articles:
![]() |
H. Jarvinen, N. Buls, P. Clerinx, S. Miljanic, D. Nikodemova, M. Ranogajec-Komor, L. Struelens, and F. d'Errico COMPARISON OF DOUBLE DOSIMETRY ALGORITHMS FOR ESTIMATING THE EFFECTIVE DOSE IN OCCUPATIONAL DOSIMETRY OF INTERVENTIONAL RADIOLOGY STAFF Radiat Prot Dosimetry, August 30, 2008; (2008) ncn239v1. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. D. Miller and M. K. Murphy Technical performance of the Luxel Al2O3:C optically stimulated luminescence dosemeter element at radiation oncology and nuclear accident dose levels Radiat Prot Dosimetry, March 1, 2007; 123(4): 435 - 442. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Miljanic, M. Ranogajec-Komor, Z. Knezevic, M. Stuhec, and M. Prokic Comparative study of LiF:Mg,Cu,Na,Si and Li2B4O7:Cu,Ag,P TL detectors Radiat Prot Dosimetry, September 1, 2006; 119(1-4): 191 - 196. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. Zorko, S. Miljanic, B. Vekic, M. Stuhec, S. Gobec, and M. Ranogajec-Komor Intercomparison of dosimetry systems based on CaF2:Mn TL detectors Radiat Prot Dosimetry, September 1, 2006; 119(1-4): 300 - 305. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Suzuki, S. Furui, I. Kobayashi, T. Yamauchi, H. Kohtake, K. Takeshita, K. Takada, and M. Yamagishi Radiation Dose to Patients and Radiologists During Transcatheter Arterial Embolization: Comparison of a Digital Flat-Panel System and Conventional Unit Am. J. Roentgenol., October 1, 2005; 185(4): 855 - 859. [Abstract] [Full Text] [PDF] |
||||