Skip Navigation

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (6)
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Miljanic, S.
Right arrow Articles by Vekic, B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Miljanic, S.
Right arrow Articles by Vekic, B.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Radiation Protection Dosimetry 106:253-256 (2003)
© 2003 Oxford University Press

Energy dependence of new thermoluminescent detectors in terms of Hp10 values

S. Miljanic, Z. Knezevic, M. Ôtuhec, M. Ranogajec-Komor, K. Krpan and B. Vekic

The aim of this work was to determine energy dependence characteristics in terms of values of the personal dose equivalant, Hp(10). The following types of thermoluminescent detectors (TLDs) were investigated: (a) two new types based on lithium borate Li2B407:Cu,In and Li2B407:Cu,In,Ag; (b) two types based on the highly sensitive material LiF:Mg,Cu,P, TLD-700H and GR 200A; (c) two well-known types of LiF:Mg,Ti detectors, TLD-100 and TLD-700 and (d) highly sensitive Al203:C detectors. TLDs previously calibrated with 137Cs gamma rays were simultaneously irradiated with X ray beams in the range of mean energies between 33 and 116 keV. The irradiations were performed with detectors in polymethyl methacrylate (PMMA) holders placed on a 30 cm x 30 cm x 15 cm water phantom with PMMA walls (ISO phantom). Measured energy responses were compared with calculated data for Hp(10) values. The results confirmed the satisfactory tissue equivalent characteristics of all investigated TLDs except Al203:C, which (due to its large energy dependence) is suitable for personal dosimetry only with an appropriate filter.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Radiat Prot DosimetryHome page
H. Jarvinen, N. Buls, P. Clerinx, S. Miljanic, D. Nikodemova, M. Ranogajec-Komor, L. Struelens, and F. d'Errico
COMPARISON OF DOUBLE DOSIMETRY ALGORITHMS FOR ESTIMATING THE EFFECTIVE DOSE IN OCCUPATIONAL DOSIMETRY OF INTERVENTIONAL RADIOLOGY STAFF
Radiat Prot Dosimetry, August 30, 2008; (2008) ncn239v1.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
S. D. Miller and M. K. Murphy
Technical performance of the Luxel Al2O3:C optically stimulated luminescence dosemeter element at radiation oncology and nuclear accident dose levels
Radiat Prot Dosimetry, March 1, 2007; 123(4): 435 - 442.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
S. Miljanic, M. Ranogajec-Komor, Z. Knezevic, M. Stuhec, and M. Prokic
Comparative study of LiF:Mg,Cu,Na,Si and Li2B4O7:Cu,Ag,P TL detectors
Radiat Prot Dosimetry, September 1, 2006; 119(1-4): 191 - 196.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
B. Zorko, S. Miljanic, B. Vekic, M. Stuhec, S. Gobec, and M. Ranogajec-Komor
Intercomparison of dosimetry systems based on CaF2:Mn TL detectors
Radiat Prot Dosimetry, September 1, 2006; 119(1-4): 300 - 305.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
S. Suzuki, S. Furui, I. Kobayashi, T. Yamauchi, H. Kohtake, K. Takeshita, K. Takada, and M. Yamagishi
Radiation Dose to Patients and Radiologists During Transcatheter Arterial Embolization: Comparison of a Digital Flat-Panel System and Conventional Unit
Am. J. Roentgenol., October 1, 2005; 185(4): 855 - 859.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.