Skip Navigation

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by W. Marsh, J.
Right arrow Articles by Wendt, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by W. Marsh, J.
Right arrow Articles by Wendt, J.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Radiation Protection Dosimetry 102:229-248 (2002)
© 2002 Oxford University Press

Uncertainty Analysis of the Weighted Equivalent Lung Dose per Unit Exposure to Radon Progeny in the Home

J. W. Marsh, A. Birchall, G. Butterweck, M.-D. Dorrian, C. Huet, X. Ortega, A. Reineking, G. Tymen, Ch. Schuler, A. Vargas, G. Vessu and J. Wendt

A parameter uncertainty analysis has been performed to derive the probability distribution of the weighted equivalent dose to lung for an adult (wlung Hlung) per unit exposure to radon progeny in the home. The analysis was performed using the ICRP Publication 66 human respiratory tract model (HRTM) with tissue weighting factor for the lung, wlung = 0.12 and the radiation weighting factor for alpha particles, wR = 20. It is assumed that the HRTM is a realistic representation of the physical and biological processes, and that the parameter values are uncertain. The parameter probability distributions used in the analysis were based on a combination of experimental results and expert judgement from several prominent European scientists. The assignment of the probability distributions describing the uncertainty in the values of the assigned fractions (ABB, Abb, AAI) of the tissue weighting factor proved difficult in practice due to lack of quantitative data. Because of this several distributions were considered. The results of the analysis give a mean value of wlung Hlung per unit exposure to radon progeny in the home of 15 mSv per working level month (WLM) for a population. For a given radon gas concentration, the mean value of wlung Hlung per unit exposure is 13 mSv per 200 Bq.m-3.y of 222Rn. Parameters characterising the distributions of wlung Hlung per unit exposure are given. If the ICRP weighting factors are fixed at their default values (ABB, Abb, AAI = 0.333, 0.333, 0.333; wlung = 0.12; and wr = 20) then on the basis of this uncertainty analysis it is extremely unlikely (P " 0.0007) that a value of Hw/Pp for exposure in the home is as low as 4 mSv per WLM, the value determined with the epidemiological approach. Even when the uncertainties in the ABB, Abb, AAI values are included then this probability is predicted to be between 0.01 to 0.08 depending upon the distribution assumed for describing the uncertainties in the ABB, Abb, AAI values. Thus, it is concluded that the uncertainties in the HRTM parameters considered in this study cannot totally account for the discrepancy between the dosimetric and epidemiological approaches.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Radiat Prot DosimetryHome page
P. F. Baias, W. Hofmann, R. Winkler-Heil, C. Cosma, and O. G. Duliu
LUNG DOSIMETRY FOR INHALED RADON PROGENY IN SMOKERS
Radiat Prot Dosimetry, September 18, 2009; (2009) ncp183v1.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
M. Puncher and A. Birchall
ESTIMATING UNCERTAINTY ON INTERNAL DOSE ASSESSMENTS
Radiat Prot Dosimetry, November 10, 2007; (2007) ncm361v1.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
N. M. Rahman, T. Iida, H. Yamazawa, S. Yokoyama, J. Moriizumi, F. Saito, and T. Ito
THE STUDY OF ACTIVITY MEDIAN AERODYNAMIC DIAMETER USING IMAGING PLATE TECHNIQUE FOR ASSESSMENT OF EFFECTIVE DOSE FROM RADON AND ITS DECAY PRODUCTS
Radiat Prot Dosimetry, June 26, 2007; (2007) ncm221v1.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
A. Mohamed
Influence of radioactive aerosol and biological parameters of inhaled radon progeny on human lung dose
Radiat Prot Dosimetry, April 18, 2005; 113(1): 115 - 122.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
J. W. Stather
Dosimetric and epidemiological approaches to assessing radon doses--can the differences be reconciled?
Radiat Prot Dosimetry, December 15, 2004; 112(4): 487 - 492.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
W. Hofmann, H. Fakir, I. Aubineau-Laniece, and P. Pihet
Interaction of alpha particles at the cellular level--implications for the radiation weighting factor
Radiat Prot Dosimetry, December 15, 2004; 112(4): 493 - 500.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
D. Nikezic and N. Stevanovic
Influence of variability of 214Pb recoil factor on lung dose
Radiat Prot Dosimetry, July 1, 2004; 109(3): 197 - 199.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.