Skip Navigation

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by S. Durham, J.
Right arrow Articles by S. Akselrod, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by S. Durham, J.
Right arrow Articles by S. Akselrod, M.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Radiation Protection Dosimetry 101:65-68 (2002)
© 2002 Oxford University Press

Design of a Finger Ring Extremity Dosemeter Based on OSL Readout of alpha-Al2O3:C

J. S. Durham, X. Zhang, F. Payne and M. S. Akselrod

A finger-ring dosemeter and reader has been designed that uses OSL readout of alpha-Al2O3:C (aluminium oxide). The use of aluminium oxide is important because it allows the sensitive element of the dosemeter to be a very thin layer that reduces the beta and gamma energy dependence to acceptable levels without compromising the required sensitivity for dose measurement. OSL readout allows the ring dosemeter to be interrogated with minimal disassembly. The ring dosemeter consists of three components: aluminium oxide powder for measurement of dose, an aluminium substrate that gives structure to the ring, and a aluminised Mylar cover to prevent the aluminium oxide from exposure to light. The thickness of the three components have been optimised for beta response using the Monte Carlo computer code FLUKA. A reader was also designed and developed that allows the dosemeter to be read after removing the Mylar. Future efforts are discussed.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Radiat Prot DosimetryHome page
P. Mancosu, D. Ripamonti, I. Veronese, M. C. Cantone, A. Giussani, and G. Tosi
Angular dependence of the TL reading of thin {alpha}-Al2O3:C dosemeters exposed to different beta spectra
Radiat Prot Dosimetry, May 16, 2005; 113(4): 359 - 365.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.