Radiation Protection Dosimetry 101:53-58 (2002)
© 2002 Oxford University Press

Characteristics and Performance of the Sunna High Dose Dosemeter using Green Photoluminescence and UV Absorption Readout Methods

S. D. Miller, M. K. Murphy, M. R. Tinker, A. Kovács and W. McLaughlin

Growth in the use of ionising radiation for medical sterilisation and the potential for wide-scale international food irradiation have created the need for robust, mass-producible, inexpensive, and highly accurate radiation dosemeters. The Sunna dosemeter, lithium fluoride injection-moulded in a polyethylene matrix, can be read out using either green photoluminescence or ultraviolet (UV) absorption. The Sunna dosemeter can be mass-produced inexpensively with high precision. Both the photoluminescent and the UV absorption reader are simple and inexpensive. Both methods of analysis display negligible humidity effects, minimal dose rate dependence, acceptable post-irradiation effects, and permit measurements with a precision of nearly 1% 1s. The UV method shows negligible irradiation temperature effects from -30 oC to +60 oC. The photoluminescence method shows negligible irradiation temperature effects above room temperature for sterilisation dose levels and above. The dosimetry characteristics of these two readout methods are presented along with performance data in commercial sterilisation facilities.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Radiat Prot DosimetryHome page
L. Oster, Y. S. Horowitz, and L. Podpalov
OSL and TL in LiF:Mg,Ti following alpha particle and beta ray irradiation: application to mixed-field radiation dosimetry
Radiat Prot Dosimetry, February 1, 2008; 128(3): 261 - 265.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.